clogged vent run (lint restriction) [S1]
high likelihood easy no part needed about 45 min
dryer runs but stays cold takes three cycles to dry a load
This is the root cause behind most no-heat calls, not just a maintenance chore: when the exhaust cannot escape, the cabinet overheats and the safety fuse cuts the heat. The source calls lint restriction the leading cause of dryer fires, so it has to be cleared end to end before any part is replaced. Time basis: no published duration, book estimate for the full vent run.
blown thermal fuse [S1]
high likelihood easy $10–$30 part about 45 min
dryer runs but stays cold drum turns but there is no heat
A one-time fuse: it blows because of the vent restriction, so replacing it without clearing the vent blows the new one again. S2 prices the parts at $15-45 and the thermostat-and-fuse job at $130-240. Time basis: no published duration, book estimate.
only one leg of the 240-volt circuit live [S1]
low likelihood easy no part needed about 15 min
drum turns but there is no heat dryer runs but stays cold
On an electric dryer the drum spins on 120 volts while the heat needs the full 240, so a partially tripped double-pole breaker looks like a dead element. Reset both poles firmly. Free, and worth checking before buying any part.